May 7, 2026
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Apr 14, 2025
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Apr 18, 2024
4 demerits
· 1 violation
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
.2537(2) Decks shall be kept in good repair. Observed deck with cracks.
View this inspection on the county portal ›
Apr 21, 2023
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
May 11, 2022
8 demerits
· 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Initial reading of pH was 6.8. CDI-pool operator corrected final pH reading to a 7.2
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
.2526(m) Keep restrooms and fixtures clean and in good repair. Dry wall in women’s bathroom shower needs repairing. Does not prevent guests from showering.
View this inspection on the county portal ›
May 21, 2021
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Apr 17, 2020
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
May 16, 2019
8 demerits
· 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Gate latches shall be 54" in height. Observec gate latch 50 inches from ground. CDI- latch was able to be moved so latch was 54" from ground.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep flow meter operational. Flow meter leaking, not operational.
View this inspection on the county portal ›
May 11, 2018
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
May 2, 2017
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
May 12, 2016
4 demerits
· 2 violations
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Repair handles and shower head on showers. Repair ceiling in men bathroom. Replace missing attic panel in women bathroom.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Replace mising back flow precvention device on hose bib on deck and chemcial room.
View this inspection on the county portal ›
Apr 29, 2015
4 demerits
· 1 violation
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed the flow meter not operating today.
View this inspection on the county portal ›
May 1, 2014
12 demerits
· 5 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some sand on pool floor. **vacuum.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Equipment room floor wet from main pool filter leak. **correct.
Forced air vent in equipment room inoperable. **repair.
Forced air vent in chemical room operates on switch. **leave fan on @ all times.
#27 · Equipment room: filter backwash discharged through an air gap −2
Backwash line pipe down in sump. **should have complete air gap.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Replace broken shower handles (2 in womens).
Handicap "hose" nozzles missing in both restrooms.
Handicap bench in men's shower broken.
#30 · Dressing and sanitary facilities: approved water source, no cross connections −2
Install vacuum breakers on all hose bibs.
View this inspection on the county portal ›