Apr 27, 2026
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Apr 22, 2026
6 demerits
· 1 violation
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
2539. Number of skimmers present does not match number of skimmers on PDSC form. PDSC form does not indicate that covers are present on pool wall to confirm that equalizer covers on pool wall are compliant.
**PERMIT DENIAL ITEM**
View this inspection on the county portal ›
Apr 9, 2025
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Apr 24, 2024
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Apr 20, 2023
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Apr 21, 2022
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Apr 8, 2021
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Apr 28, 2020
4 demerits
· 1 violation
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Observed debris in skimmer baskets.
View this inspection on the county portal ›
Apr 26, 2019
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
May 7, 2018
6 demerits
· 1 violation
#6 · Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ −6
PDSC paperwork stated Skimmers were plugged. Inspection revealed they were not plugged. CDI- Skimmers plugged. Lines drained of water. New PDSC paperwork submitted.
View this inspection on the county portal ›
Jul 3, 2017
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Jul 19, 2016
8 demerits
· 3 violations
#14 · Pool maintenance: spa timer working properly −4
Spa timer ran for at least 20 minutes. ** Spa timer should cut off at 15 minutes or less. Resolve/ replace.
Note: Spa is not heated.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Forced air ventilation in equipment & chemical rooms not working. (No natural cross draft ventilation.) ** Keep forced air ventilation operational.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Hot water ~116F at lavatories in restrooms. ** Maximum allowed is 110F.
One toilet in men's restroom out of order. ** Resolve.
View this inspection on the county portal ›
Jun 15, 2015
14 demerits
· 4 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Two of four weirs either damaged or stuck. Keep in good repair. Skimmers not easily accessible due to pine needles placed over top. Keep accessible.
#14 · Pool maintenance: spa timer working properly −4
Spa timer >15 minutes. Non-heated pool. Maintain at 15 min or less.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter stuck. Keep operable.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Water >115 F in restrooms. Maintain at 110 F or below.
View this inspection on the county portal ›
May 29, 2014
18 demerits
· 4 violations
#2 · Water quality: disinfectant residual provided by −6
Chlorine in tested and found to be at 0ppm. Operator, Kelly Tulacz called pool personnel. Personnel came out immediately; chorine corrected to 3ppm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Operator advised pool personnel maintain records in office room as pool opened on Memorial Day weekend. Pool records book was provided, but no documentation of daily records and equipment being maintained. INTENT TO SUSPEND ISSUED. Return visit by June 27, 2014 to check for daily chemical records and equipment checks.
#9 · Pool maintenance: depth markings and no diving markers or signs visible and properly located −4
One of three depth markers completely missing. Square where depth marker was cemented in is still present. Replace depth marker.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Raised decking at interior gate on the left of the main pool between the spa and main pool is inhibiting gate from closing just before the latching system. If gate is pulled, then it closes completely and self latches. Repair so that gate will self close and self latch.
View this inspection on the county portal ›