Apr 30, 2026
6 demerits
· 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed mens locker room door not closing far enough to engage the audible alarm. CDI- door repaired to be self-closing and alarmed.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed water on pump room floor due to leak at valve connected to sand filter.
View this inspection on the county portal ›
Dec 10, 2025
10 demerits
· 2 violations
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. Observed doors to both locker rooms where door chime was not operational. CDI- chime repaired, doors were self-closing and audibly alarmed.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed telephone number posted incorrect. CDI- correct number posted, phone working as required.
View this inspection on the county portal ›
Feb 25, 2025
12 demerits
· 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 8.0. Permit suspended.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable. Observed emergency phone non operational.
View this inspection on the county portal ›
Dec 10, 2024
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Apr 10, 2024
6 demerits
· 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder not securely attached to pool deck. Observed ladder missing rubber end caps.
.2517(e) Secure starting platforms from use by removal; covering; or signage and active supervision. Observed no restricted access to starting platforms; no signage posted.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
.2537(b) All gates and doors shall be self-closing, self-latching. Observed mens locker room door not completely audibly alarming or self latching. Intent to suspend permit issued. Repair within 30 days.
View this inspection on the county portal ›
Nov 13, 2023
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Feb 15, 2023
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Nov 16, 2022
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Mar 23, 2022
6 demerits
· 1 violation
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall remain operable.
Emergency phone was found not to have audible ring on the call-back. A problem with low volume on the call-back ring/no sound on the call-back ring was noted on the previous inspection report as a General Comment dated 7/6/2021. It was recommended in that report by C. Elmore, the assigned Health Inspector, that the ringer be corrected to ensure the call-back ring could be heard over any ambient noise. Today there was not a call-back ring sound that was detectible by C. Elmore or CPO T. Bumgarner. This is a closure item as call-back capability from emergency services is needed. That is why a call back number is required to be assigned to the phone itself as call-back functionality is considered to be part of the proper operability of the emergency phone. Pool is closed by order of the Health Department for rules violation. The pool cannot be reopened until the phone call back ringer is properly corrected such that it can be heard over the typical ambient noise of the pool in use, and C. Elmore has verified the correction. Contact information for C. Elmore is 704-507-6814. Contact C. Elmore when correction is made.
View this inspection on the county portal ›
Jul 6, 2021
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Nov 4, 2020
0 demerits
· 0 violations
No violations were recorded for this inspection.
View this inspection on the county portal ›
Jan 28, 2020
6 demerits
· 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed some gaps in the log record. Gaps not sufficient enough to take permit action at this time. Do not leave gaps in the log record. If pool is closed, mark the day as "Closed". No permit action taken at this time.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed some chipping on the surface of the dive platforms.
View this inspection on the county portal ›
Nov 8, 2019
12 demerits
· 2 violations
#3 · Water quality: pool water pH −6
.2535(1) Maintain pH at 7.2 to 7.8. Observed pool pH at 6.8. Immediate suspension issued.
#22 · Premises: emergency telephone provided −6
.2530(f) Emergency phone shall be accessible to all pool users. Observed plastic casing that emergency phone is stored in to be unopenable. CDI- Phone box was pryed open with metal bar by employee.
View this inspection on the county portal ›
Feb 26, 2019
2 demerits
· 1 violation
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed some wear and damage to the tread on some of the dive blocks. Maintain the blocks in good repair so that they do not become a hazard to the swimmers.
View this inspection on the county portal ›
Oct 25, 2018
16 demerits
· 4 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder removed from 1 corner. Ladders must be provided at intervals no greater than 75ft. apart. Ladder can be removed due to use needs of the pool, but it must be replaced when the use is completed. This was noted on previous 2 inspections. Replace ladder.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed 1 of the 2 body hooks have been wedged against a loose metal bar in the ventilation system. This made the hook difficult to remove for deployment in a life-threating emergency. C. Elmore removed the body hook and placed it along a wall. Both hooks must be available for use in case of an emergency. -CDI.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed doors leading into the pool area to be self-closing, but not self latching. These doors must be audibly alarmed, or be made fully self-closing/self-latching. The alarms are either missing, missing parts, or are non-functional. The door were correct as of 2/28/18 during an on-site visit by C. Elmore to evaluate compliance. They are in violation on this inspection date. This was noted on the previous 2 inspections. Doors must either be fully self-closing and self-latching or be audibly alarmed to alert upon opening.
Deadline for compliance issued. I.T.S.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck coating to be peeling up and presenting a damaged/worn surface. This must be repaired to provide a smooth deck free from hazards and easy to clean. Failure to correct this has resulted in a deadline for compliance. Observed pole holes left open and uncapped. Cap the holes or replace the poles. I.T.S. This was noted on the previous 2 inspections, one of which was on 10/26/17.
View this inspection on the county portal ›
Feb 20, 2018
14 demerits
· 4 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder removed from 1 corner. Ladders must be provided at intervals no greater than 75ft. apart. Ladder can be removed due to use needs of the pool, but it must be replaced when the use is completed. This was noted on previous inspection. Replace ladder.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Some doors onto pool deck are not self-latching. The are self closing. All doors leading onto the pool deck (entrance doors, locker room doors, staff access doors) that lead to the outside must either be self-closing and self-latching, or be audibly alarmed to alert when the door is opened. This was noted on the previous inspection and corrected. Today, none of the alarms installed functioned when first checked. Some were broken, some had sensors missing, and at least one seemed to have been intentionally turned off. C. Elmore corrected two alarms, but was unable to correct the others. One door in the back corner of the pool enclosure (left most door of the pair, grey in color) was found to be not fully self closing. These doors must be corrected and kept in compliance. I.T.S. Issued. Expires 3/22/18.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck coating to be peeling up and presenting a damaged/worn surface. This must be repaired to provide a smooth deck free from hazards and easy to clean. Failure to correct this may result in a deadline for compliance. C. Elmore has been advised that the deck will be resurfaced in the spring. This was noted on the previous inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair it.
View this inspection on the county portal ›
Oct 26, 2017
12 demerits
· 4 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladder removed from 1 corner. Ladders must be provided at intervals no greater than 75ft. apart. Replace ladder.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck coating to be peeling up and presenting a damaged/worn surface. This must be repaired to provide a smooth deck free from hazards and easy to clean. Failure to correct this may result in a deadline for compliance on the next pool inspection.
Observed water sports goals to be closer thatn 5ft. from pool edge. This is a safety hazard for tripping. Items were moved back. -C.D.I. Keep items 5 ft. back from pool edge when not in use.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter stuck. Repair it.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed chemicals kept in pump room. Separate chemcial room is best.
View this inspection on the county portal ›
Feb 15, 2017
8 demerits
· 3 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed ladders removed from 3 of 4 corners of pool. Provide ladders at intervals no greater than 75 feet along pool deck.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed pitting in pool deck. Repair. Also observed basketball and handball goals with in 5 feet of pools edge. Maintain 5 feet of deck clearance at all points.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on pump room floor. Repair leak.
View this inspection on the county portal ›
Nov 21, 2016
12 demerits
· 4 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed minor amount of debris on pool floor. Keep pool floor free of debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed several loose ladders. Tighten loose ladders.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed trashcan, basketball hoop and water polo nets withing 6 feet of pools edge maintasin 6 ft of clearance at all points. Also observed areas of minor pitting around pool deck. Repair these areas.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water onb pump room floor. Repair leak.
View this inspection on the county portal ›
Jan 28, 2016
22 demerits
· 7 violations
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed minor amount of debris on pool floor. Keep pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in gutter system. Keep gutters free of debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loos ladder at deep end of pool. Tighten loose ladder.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed some pitting in areas of deck. Observed pitting at paw areas as well.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Flow meter bead appears to be stuck. Repair.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed water on pumproom floor. Repair leak.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in boys locker room at 115 degrees. Hot water in restrooms/locker roomsshould not exceed 110 degrees.
View this inspection on the county portal ›
Oct 22, 2015
18 demerits
· 5 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed minor amount of debris in gutters. Keep gutters free of debris.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed one loose ladder. Repair. Also observed 1 ladder missing. Replace ladder to maintain 75ft intervals between ladders.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed items within 5 feet of pools edge. Maintain 5 feet of deck clearance at all points.
#22 · Premises: emergency telephone provided −6
Emergency phone was inoperable at time of visit. Repair. Immediate suspension issued.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in restrooms at 118 degrees. Hot water should not exceed 110 degrees.
View this inspection on the county portal ›
Feb 11, 2015
12 demerits
· 3 violations
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed the covering of the ring bouys to be damaged. They are not unusable currently, but they must be replaced due to the damage. Failure to replace them may result in pool closure in future inspections.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed deck damage due to peeling coating in some places. Repair the deck to prevent it from becoming a trip hazard.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in bathrooms to be at least 114F. It is not to exceed 110F.
View this inspection on the county portal ›
Dec 11, 2014
4 demerits
· 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed loose ladders. Ensure that all ladders/ handrails are tight.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed hot water in boys locker room at 117 degrees F. Hot water should not exceed 110 degrees F in restrooms.
View this inspection on the county portal ›
Jan 21, 2014
34 demerits
· 9 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed rusted gutters. Keep in good repair.
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed handrail loose on left shallow ladder. Tighten. Observed diving platforms not secure. Provide constant supervision and secure from use by removal, covering or signage.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Observed pool >3000 sq ft. 60' x 77.5'. Second body hook not provided. Corrected during inspection.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed door to pool propped open. Keep closed.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Observed damage to deck at bear paw. Keep in good repair. Observed bball hoops directly next to pool. Maintain 5 ft deck clearance.
#22 · Premises: emergency telephone provided −6
Observed no dialing instructions. Posted to dial 9 to dial out. Provide dial 9-911 for emergencies. Corrected during inspection.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed 2 multi-ports leaking. Repair. Observed flow meter on line out of pump. Provide on return line.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed approx 1" of water on pump room floor. Keep floor dry.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
Observed water in restrooms >120 F. Maintain at 110 F or below.
View this inspection on the county portal ›
Oct 31, 2013
6 demerits
· 2 violations
#11 · Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair −2
Observed 1 loose ladder. Tighten ladder.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
Observed flow meter not operational. Repair flowmeter.
View this inspection on the county portal ›