28demerits
PROSE MCCULLOUGH STATION
8424 N TRYON ST, Charlotte, NC 28262
Year-Round Swimming Pool · NC permit/State ID 2060530744
Latest result28 demerits
Last inspectedNov 2, 2026
Inspections on record6
On record sinceMay 3, 2024
This facility type is scored in demerits: lower is better (0 = no violations found).
Score history
May 3, 2024Lower is betterNov 2, 2026
Inspections & violations
Nov 2, 2026 28 demerits · 7 violations
Inspector comments: 16 - Window limiters required on windows. Could not access. Ensure all windows are limited at 4" or less.
Immediate suspension issued for:
.2535 - maintain pool chlorine at least 1.0 ppm through feeder.
.2530 - replace ring buoy with USCG approved ring buoy.
Once corrected, contact Katie at 704-309-5494 or katie.rudisill@mecknc.gov to reopen the pool. Pool closed signs posted during the inspection.
Ty Griffin present during the inspection. CPO viewed while onsite.
Permit Restrictions: 1) Flow meter must remain operable. Flow shall be maintained at 106 gpm to 138 gpm to meet turnover and flow restriction of suction pipe sizing.
#2 · Water quality: disinfectant residual provided by −6
Chlorine at 0.6 ppm. Operator turned up feeder while onsite but chlorine did not correct. Maintain chlorine at least 1.0 ppm through approved NSF chlorinator. Immediate Suspension issued.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Some months with CYA and Total alkalinity readings not weekly. Ensure weekly record keeping.
Total alkalinity reagent expired. Replace reagent.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Algae build-up on plaster on walls, between contrasting color band grout, and around main drains. Continue to monitor and treat as needed.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Water level low, just at skimmer line. Ensure water level is high enough to ensure skimmers are operating per NSF requirement.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook not secured to pole. Corrected during the inspection.
Grab rope on ring buoy starting to deteriorate due to weathering. Replace ring buoy with USCG approved buoy. Immediate Suspension issued.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Pump room floor wet. Operator bled filter after backwash. Ensure floor kept dry. Could not identify any leaks.
Some chemicals stored in pump room. Ensure all chemicals stored in chemical storage room.
Fan turned off in pump room/chemical storage room. Turned on during the inspection. Ensure forced draw ventilation is operable at all times.
#29 · Dressing and sanitary facilities: required fixtures provided, clean, and in good repair −2
No soap in men's restroom. Provide soap.
Feb 18, 2026 10 demerits · 2 violations
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no weekly records for total alkalinity or cyanuric acid for February. Maintain as required.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#22 · Premises: emergency telephone provided −6
Observed emergency phone inoperable at time of visit. Corrected onsite.
.2530(f) Emergency phone shall remain operable.
Oct 23, 2025 16 demerits · 3 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Repeat. Observed debris in skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
.2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Body hook observed attached to a telescoping pole. Body hook attached to a non-telescoping pole during inspection. CDI
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope for ring buoy tangled. Untangled during inspection. CDI
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Signage was incorrect for the pool telephone number. Correct pool telephone number posted during inspection. CDI
Feb 25, 2025 20 demerits · 4 violations
Inspector comments: Issued immediate suspension for inadequate chlorine levels and inoperable emergency phone. Pool is to remain closed until items are repaired. Call James Bjorneboe at 704-507-6820 once items are corrected to schedule re-visit.
#2 · Water quality: disinfectant residual provided by −6
Observed no chlorine in pool. Maintain chlorine at a minimum of 1.0ppm.
.2535(4) Maintain chlorine at least 1.0 ppm.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Observed leaves and debris on pool floor. Keep pool floor free of debris.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#22 · Premises: emergency telephone provided −6
Unable to connect to 911 via emergency phone. Repair.
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system.
Oct 24, 2024 10 demerits · 2 violations
Inspector comments: Issued intent to suspend for gate not self-closing/ self-latching. Requires repair within 30 days. Please call James Bjorneboe at or 704-507-6820 once repairs have been made.
General Comment: Volume on emergency phone was very low. Look into potential issue with phone volume.
#15 · Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located −6
Body hook not attached to pole. Hook must remain attached to pole at all times. Corrected onsite.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed 1 gate not self-closing/ self- latching. Repair.
.2537(b) All gates and doors shall be self-closing, self-latching.
May 3, 2024 0 demerits · 0 violations
Inspector comments: Observed no non-compliant condition.
Permit Restriction:
1) Flow meter must remain operable. Flow shall be maintained at 106 gpm to 138 gpm to meet turnover and flow restriction of suction pipe sizing.
2) No restriction on feature pump.
No violations were recorded for this inspection.
Source: Mecklenburg County Public Health – Environmental Health public inspection portal (search for “PROSE MCCULLOUGH STATION” or State ID 2060530744). Inspection type (routine vs. follow-up) is not published in the county's data.