‹ Back to search

14demerits

JUNCTION 49 - POOL

7521 TWITTER LN, Charlotte, NC 28213
Year-Round Swimming Pool · NC permit/State ID 2060530767
Latest result14 demerits
Last inspectedOct 29, 2026
Inspections on record6
On record sinceOct 25, 2024

This facility type is scored in demerits: lower is better (0 = no violations found).

Score history

01224 Oct 25, 2024: 12Dec 4, 2024: 24Feb 27, 2025: 6Jul 29, 2025: 6Jan 13, 2026: 6Oct 29, 2026: 14
Oct 25, 2024Lower is betterOct 29, 2026

Inspections & violations

Oct 29, 2026 14 demerits · 3 violations
Inspector comments: - Operator has only just recently taken over as of 10/20/26 and the previous operator kept an electronic record log that became inaccessible when the previous operator was fired. New logs only begin from 10/20/26 onwards. New operator was advised to ensure logs can be accessed in the event of them not being on site. - Pool rules signage (x4) all stated that the pool hours of operation were 9am-8pm despite the pool not being approved for night swimming. Operator corrected the signs to stated 9am-Dusk as the pool hours. - Phone operation system was chnaged over to a Kings III system since the last inspection. - Required flow meter reading is between 110-138pgm or the pump must be set to 3450rpm.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. - Observed the current records to not include a main drain check. CDI - Operator added a main drain check to the daily record sheet.
#22 · Premises: emergency telephone provided −6
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Observed the sign posted at the emergency phone to not be provided with a callback number. CDI - Operator printed out phone number label and posted at the emergency phone sign.
#24 · Equipment room: approved pump, filter, and flow meter operating properly −4
.2518(g) Keep the flow meter operational. - Observed the flow meter to not be functional at the time of the inspection with the bobber reading 0ppm and being stuck at the bottom. CDI - Flow meter repaired at the time of the inspection and flow observed at 125gpm.

View this inspection on the county portal ›

Jan 13, 2026 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in some skimmers. Ensure that skimmers are kept free of debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed bag on sodium bicarbonate on chemical storage room floor. Corrected on site. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.

View this inspection on the county portal ›

Jul 29, 2025 6 demerits · 2 violations
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed debris in skimmers. Keep skimmers free of debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#25 · Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure −2
Observed leaky chlorinator in pump room causing water to stand on pump room floor. Repair. .2533(d) Pump room floor shall be kept dry and free of standing water.

View this inspection on the county portal ›

Feb 27, 2025 6 demerits · 1 violation
Inspector comments: All immediate suspension items from previous inspection (pH, chlorine, and doors to deck) have been corrected.
#22 · Premises: emergency telephone provided −6
No phone number posted at emergency phone. Corrected on site.

View this inspection on the county portal ›

Dec 4, 2024 24 demerits · 5 violations
Inspector comments: Issued immediate suspension for out of compliance chlorine and pH levels. Pool is to remain closed until items are corrected. Please call James Bjorneboe at 704-507-6820 to schedule revisit. General comment: Consider using emergency phone that can transmit both address and phone number to 911.
#2 · Water quality: disinfectant residual provided by −6
Observed no chlorine in pool. Maintain chlorine at a minimum of 1.0ppm .2535(4) Maintain chlorine at least 1.0 ppm.
#3 · Water quality: pool water pH −6
Observed pH at 8.4. Maintain between 7.2 and 7.8. .2535(1) Maintain pH at 7.2 to 7.8.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
Observed no daily/weekly records onsite. Keep and maintain daily/weekly written records as required. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
#8 · Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris −4
Observed excessive debris in skimmers. Keep skimmers free of debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
#16 · Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained −4
Observed two sets of doors not self closing/ self latching. .2537(b) All gates and doors shall be self-closing, self-latching.

View this inspection on the county portal ›

Oct 25, 2024 12 demerits · 3 violations
Inspector comments: OSV to pool with Hot Springs Pools and Harkins Builders for return construction. Construction final passed. All items from previous site visit corrected. Permit issued for no night swimming. A follow-up inspection will be conducted by EHS within 30 to 60 days of permit issuance. Ensure log book is provided for follow-up. Holds released in Winchester. Permit sticker provided during the site visit. The State permit will be available online by end of business 10/25. Note: Mirrors verified with backing tape for restrooms. See permanent file. Note: All resident rooms that open on to pool deck were verified with window limiters. Caution: Emergency phone is cellular and not transferring address to 911. The Health Department highly recommends that a phone is installed that can transfer both the address and phone number to 911 for emergency response. Swimming Pool Permit Restrictions: 1) Pump shall remain at 3450 RPM or flow meter must remain operable with flow at 110 gpm to 138 gpm to meet turnover and flow restriction of suction lines. Pentair Intelliflo3 VSF 011075, 3 hp pump with (2) Hayward WG1031BHF2 drain covers. (5) skimmers with EQ lines plugged inside and capped on underside. Max Depth 4 ft.; Pool Width 38 ft.; Rope Length 50 ft.
#5 · Water quality: daily written records of water quality and test kit kept on site −4
No log book. Operator had not yet taken over the pool. Ensure daily record keeping for chlorine, pH and main drain checks. Maintain weekly record keeping for cyanuric acid and total alkalinity.
#7 · Pool maintenance: pool walls and floor kept clean, free of debris and in good repair −4
Some debris on pool floor. Keep clean.
#17 · Premises: decks unobstructed, properly drained, free of trip hazards −4
Some standing water near shower. Outside of required deck space. If area begins to mildew or becomes a slip hazard, may require repair in future.

View this inspection on the county portal ›